1. ISO 4126-4 Mass Flow Capacity Equation
q_m = (p_0 × A × K_dr × C) / sqrt( (Z × T_0) / M )
Where p_0 is absolute relieving pressure (bar abs), A is throat flow area (mm²), K_dr is certified discharge coefficient (0.75 ~ 0.84 for XZ-790LP), C is isentropic expansion coefficient, M is molecular weight (LNG: 16.04, N2: 28.01, O2: 32.00, Ar: 39.95 kg/kmol), T_0 is relieving temperature (K), and Z is compressibility factor.
2. Master Sizing Table: API 526 Orifice Capacities (Liquid Nitrogen, Nm³/h)
Orifice |
Area (cm²) |
Flange (In x Out) |
@ 1.0 MPa |
@ 2.5 MPa |
@ 5.0 MPa |
D |
0.71 |
1" x 2" CL150/300 |
875 Nm³/h |
2,040 Nm³/h |
3,980 Nm³/h |
E |
1.26 |
1" x 2" CL150/300 |
1,550 Nm³/h |
3,620 Nm³/h |
7,060 Nm³/h |
F |
1.98 |
1.5" x 2" CL150/300 |
2,440 Nm³/h |
5,690 Nm³/h |
11,100 Nm³/h |
G |
3.25 |
1.5" x 2" CL150/300 |
4,000 Nm³/h |
9,340 Nm³/h |
18,220 Nm³/h |
H |
5.06 |
2" x 3" CL150/300 |
6,230 Nm³/h |
14,540 Nm³/h |
28,370 Nm³/h |
J |
8.30 |
2" x 3" CL150/300 |
10,220 Nm³/h |
23,850 Nm³/h |
46,530 Nm³/h |
K |
11.86 |
3" x 4" CL150/300 |
14,600 Nm³/h |
34,080 Nm³/h |
66,490 Nm³/h |
L |
18.41 |
3" x 4" CL150/300 |
22,670 Nm³/h |
52,900 Nm³/h |
103,200 Nm³/h |
M |
23.23 |
4" x 6" CL150/300 |
28,600 Nm³/h |
66,750 Nm³/h |
130,200 Nm³/h |
P |
41.16 |
4" x 6" CL150/300 |
50,680 Nm³/h |
118,250 Nm³/h |
230,760 Nm³/h |
Q |
71.29 |
6" x 8" CL150/300 |
87,780 Nm³/h |
204,850 Nm³/h |
399,700 Nm³/h |
R |
103.20 |
6" x 8" CL150/300 |
127,080 Nm³/h |
296,550 Nm³/h |
578,600 Nm³/h |
T |
167.74 |
8" x 10" CL150/300 |
206,550 Nm³/h |
482,000 Nm³/h |
940,500 Nm³/h |
3. Valve Dimensions & Mechanical Weight Matrix
Size (In x Out) |
Rating (ASME) |
L1 x L2 (mm) |
Height H (mm) |
Pilot Wt (kg) |
1" x 2" (DN25/50) |
Class 150 x 150 |
105 x 114 |
385 mm |
22 kg (-51%) |
1.5" x 2" (DN40/50) |
Class 300 x 150 |
124 x 121 |
425 mm |
31 kg (-50%) |
2" x 3" (DN50/80) |
Class 300 x 150 |
137 x 124 |
480 mm |
45 kg (-54%) |
3" x 4" (DN80/100) |
Class 300 x 150 |
156 x 162 |
590 mm |
78 kg (-55%) |
4" x 6" (DN100/150) |
Class 300 x 150 |
181 x 229 |
710 mm |
125 kg (-57%) |
6" x 8" (DN150/200) |
Class 300 x 150 |
240 x 241 |
860 mm |
210 kg (-60%) |
8" x 10" (DN200/250) |
Class 300 x 150 |
276 x 280 |
1020 mm |
380 kg (-60%) |
4. Factory Verification: What EPC Buyers Must Demand

In-House Vacuum-Insulated Liquid Nitrogen (LIN) Storage Tank at Factory
![]() |
![]() |
![]() |
| Automated Multi-Channel Digital Test Console Recording Cold Pop/Reseat Curves | Submerged Vacuum Cryostat Wells for ISO 21013-4 Proof Cycle Validation | Certified Cleanroom Assembly Facility for Oxygen-Service Degreased Valves |
5. Standard Tender Specification Clause for Bidding Documents
"All safety relief valves for cryogenic service down to -196°C shall be of the pilot-operated type in accordance with ISO 4126-4 and GB/T 40011-2021. The pilot valve assembly shall feature a non-flowing pilot mechanism with an external extended thermal decoupling loop. Valve seat tightness shall achieve zero-bubble leakage per API 527 at 98% of set pressure. Valve reseat blowdown shall not exceed 7% of set pressure. The manufacturer must possess an in-house liquid nitrogen test station and provide certified EN 10204 Type 3.1 test records confirming that 100% of the valves were subjected to popping, reseating, and seat tightness verification at -196°C in liquid nitrogen prior to shipment."