The Cryogenic Safety Valve Procurement Handbook(ISO 4126-4 Sizing Equations, API 526 Orifice Discharge Capacities, and -196°C Liquid Nitrogen Verification Protocol)

2026-10-23 10:56:51
The Cryogenic Safety Valve Procurement Handbook(ISO 4126-4 Sizing Equations, API 526 Orifice Discharge Capacities, and -196°C Liquid Nitrogen Verification Protocol)

1. ISO 4126-4 Mass Flow Capacity Equation

q_m = (p_0 × A × K_dr × C) / sqrt( (Z × T_0) / M )

Where p_0 is absolute relieving pressure (bar abs), A is throat flow area (mm²), K_dr is certified discharge coefficient (0.75 ~ 0.84 for XZ-790LP), C is isentropic expansion coefficient, M is molecular weight (LNG: 16.04, N2: 28.01, O2: 32.00, Ar: 39.95 kg/kmol), T_0 is relieving temperature (K), and Z is compressibility factor.

2. Master Sizing Table: API 526 Orifice Capacities (Liquid Nitrogen, Nm³/h)

Orifice

Area (cm²)

Flange (In x Out)

@ 1.0 MPa

@ 2.5 MPa

@ 5.0 MPa

D

0.71

1" x 2" CL150/300

875 Nm³/h

2,040 Nm³/h

3,980 Nm³/h

E

1.26

1" x 2" CL150/300

1,550 Nm³/h

3,620 Nm³/h

7,060 Nm³/h

F

1.98

1.5" x 2" CL150/300

2,440 Nm³/h

5,690 Nm³/h

11,100 Nm³/h

G

3.25

1.5" x 2" CL150/300

4,000 Nm³/h

9,340 Nm³/h

18,220 Nm³/h

H

5.06

2" x 3" CL150/300

6,230 Nm³/h

14,540 Nm³/h

28,370 Nm³/h

J

8.30

2" x 3" CL150/300

10,220 Nm³/h

23,850 Nm³/h

46,530 Nm³/h

K

11.86

3" x 4" CL150/300

14,600 Nm³/h

34,080 Nm³/h

66,490 Nm³/h

L

18.41

3" x 4" CL150/300

22,670 Nm³/h

52,900 Nm³/h

103,200 Nm³/h

M

23.23

4" x 6" CL150/300

28,600 Nm³/h

66,750 Nm³/h

130,200 Nm³/h

P

41.16

4" x 6" CL150/300

50,680 Nm³/h

118,250 Nm³/h

230,760 Nm³/h

Q

71.29

6" x 8" CL150/300

87,780 Nm³/h

204,850 Nm³/h

399,700 Nm³/h

R

103.20

6" x 8" CL150/300

127,080 Nm³/h

296,550 Nm³/h

578,600 Nm³/h

T

167.74

8" x 10" CL150/300

206,550 Nm³/h

482,000 Nm³/h

940,500 Nm³/h

3. Valve Dimensions & Mechanical Weight Matrix

Size (In x Out)

Rating (ASME)

L1 x L2 (mm)

Height H (mm)

Pilot Wt (kg)

1" x 2" (DN25/50)

Class 150 x 150

105 x 114

385 mm

22 kg (-51%)

1.5" x 2" (DN40/50)

Class 300 x 150

124 x 121

425 mm

31 kg (-50%)

2" x 3" (DN50/80)

Class 300 x 150

137 x 124

480 mm

45 kg (-54%)

3" x 4" (DN80/100)

Class 300 x 150

156 x 162

590 mm

78 kg (-55%)

4" x 6" (DN100/150)

Class 300 x 150

181 x 229

710 mm

125 kg (-57%)

6" x 8" (DN150/200)

Class 300 x 150

240 x 241

860 mm

210 kg (-60%)

8" x 10" (DN200/250)

Class 300 x 150

276 x 280

1020 mm

380 kg (-60%)

4. Factory Verification: What EPC Buyers Must Demand

image (42).jpg

In-House Vacuum-Insulated Liquid Nitrogen (LIN) Storage Tank at Factory

image (43).jpg image (44).jpg image (45).jpg
Automated Multi-Channel Digital Test Console Recording Cold Pop/Reseat Curves Submerged Vacuum Cryostat Wells for ISO 21013-4 Proof Cycle Validation Certified Cleanroom Assembly Facility for Oxygen-Service Degreased Valves

5. Standard Tender Specification Clause for Bidding Documents

"All safety relief valves for cryogenic service down to -196°C shall be of the pilot-operated type in accordance with ISO 4126-4 and GB/T 40011-2021. The pilot valve assembly shall feature a non-flowing pilot mechanism with an external extended thermal decoupling loop. Valve seat tightness shall achieve zero-bubble leakage per API 527 at 98% of set pressure. Valve reseat blowdown shall not exceed 7% of set pressure. The manufacturer must possess an in-house liquid nitrogen test station and provide certified EN 10204 Type 3.1 test records confirming that 100% of the valves were subjected to popping, reseating, and seat tightness verification at -196°C in liquid nitrogen prior to shipment."