Safety Relief Valve Sizing: An API 520 Worked Example from Relieving Scenario to Orifice Selection

2026-11-17 13:23:36
Safety Relief Valve Sizing: An API 520 Worked Example from Relieving Scenario to Orifice Selection

Safety Relief Valve Sizing: An API 520 Worked Example from Relieving Scenario to Orifice Selection

Shanghai Xia Zhao Valve · Engineering Note for API 520 Part I / API 521 / API 526 Applications

A separator drum on a natural-gas feed lists control-valve failure and blocked discharge as relieving scenarios. The buyer’s datasheet recorded a DN50 inlet, PN16 body, and 316 trim—but no required relieving rate, no split between superimposed and built-up back pressure, and no compressibility or relieving temperature. A valve chosen to match the flange rather than the required effective discharge area either cannot keep up with the relieving rate, or it chatters and destroys the seating surfaces within a few lifts. Sizing is the step that turns a scenario into an orifice letter; everything downstream—body rating, trim, bellows, seat tightness—depends on that area being correct first.

What sizing actually fixes

Sizing answers one question: for the governing relieving scenario, what effective discharge area A does the valve need? API 521 identifies the scenarios that must be evaluated—fire, blocked discharge, utility failure, control failure, thermal expansion, external heat, reflux loss, and similar cases. API 520 Part I supplies the equations and correction factors; API 526 lists the standardized effective orifice areas behind letter designations D through T. The scenario that governs is the one demanding the largest area, not the one written first on the P&ID.

Before the equation is opened, the datasheet must carry: the relieving rate W or Q; the set pressure and allowable overpressure; the relieving pressure P1 in absolute units; superimposed and built-up back pressure; the relieving temperature T; molecular weight M; ratio of specific heats k; compressibility Z; liquid viscosity; fluid phase and any flashing or entrainment; and whether an upstream rupture disk is installed. A valve reused across several scenarios must satisfy every listed case; the worst case governs.

Gas and vapor: the equation and what each factor means

For critical-flow gas or vapor, the API 520 relationship in inch-pound form reduces to A = W·√(T·Z/M) / (C·Kd·P1·Kb·Kc), where A is the required effective discharge area, W the relieving mass rate, T the relieving temperature, Z the compressibility, M the molecular weight, C the gas constant derived from the ratio of specific heats k, Kd the discharge coefficient, P1 the relieving pressure in absolute units, Kb the back-pressure correction, and Kc the combination factor for an upstream rupture disk.

C: a function of k; a higher ratio of specific heats gives a higher C and a smaller required area. Use k at relieving conditions, not the ambient handbook value. Kd: the discharge coefficient. 0.975 is the conventional spring-loaded reference in API 520, but the certified value for the selected valve and trim must be taken from the manufacturer. P1: relieving pressure equals set pressure plus allowable overpressure, expressed absolute; gauge readings must be converted before entering the equation. Kb: capacity correction for back pressure on a balanced-bellows valve, read from the manufacturer’s curve at the actual total back pressure. For conventional and pilot-operated valves Kb is taken as 1.0. Kc: combination factor when a rupture disk is installed upstream; the disk adds resistance and changes the effective inlet condition.

When downstream pressure keeps the flow subcritical, an additional subcritical factor F2 applies; the critical-flow equation must not be forced onto a subcritical case. Liquid sizing carries a viscosity correction, and high viscosity requires a larger orifice than the incompressible-flow estimate. Flashing liquid or liquid entrained in vapor cannot be sized with the gas equation alone: use a recognized two-phase method and confirm the result in vendor sizing software.

Worked example: walking the inputs to an orifice letter

The following is an illustrative walkthrough of the method, not a final rating. Vapor relief case: relieving rate W = 12 000 kg/h; relieving pressure P1 to be confirmed on an absolute basis; relieving temperature 150 °C; molecular weight 44; k = 1.25; compressibility Z taken from the equation of state at relieving conditions; balanced-bellows valve with superimposed plus built-up back pressure of 0.35 barg; no upstream rupture disk.

1. Confirm the governing scenario and the accumulation limit allowed by the governing code and scenario; record the overpressure percentage on the datasheet. 2. Convert P1 to absolute pressure and T to absolute temperature; pull Z and k at relieving conditions. 3. Compute C from k, then compute required A using the selected Kd, Kb, and Kc. 4. Compare A against the API 526 effective orifice areas (D through T) and select the smallest letter whose effective area is at least A. 5. Re-check Kb at the actual total back pressure; if the bellows curve derates capacity, the selected area must absorb that derating. 6. Verify that inlet piping pressure drop stays within the API 520 limit, commonly no more than 3% of set pressure, so the valve does not chatter; verify outlet capacity against the calculated built-up back pressure.

The numbers above walk through the method only. Final sizing must be run with confirmed fluid properties, the manufacturer’s certified Kd and Kb curves, and the governing-code accumulation limit. An orifice letter chosen from a handbook estimate is not a purchase specification.

Safety Relief Valve Sizing: An API 520 Worked Example from Relieving Scenario to Orifice Selection

Figure 1: Cutaway spring-loaded relief valve—inlet, nozzle, disc, guide, stem, bellows, and outlet.

Liquid, thermal expansion, and two-phase cases that get mis-sized

Liquid relief cases are often sized as if the fluid were incompressible at low viscosity; the viscosity correction can move the selection up an orifice letter, and entrained solids or polymerizing service change the trim and seat choice as well. Liquid trapped between closed valves expands thermally and needs a small thermal-relief device; that case is not served by the main process PSV sized for a vapor fire case. Two-phase relief—flashing liquid, or liquid carried in vapor—requires a dedicated two-phase method and vendor software. Sizing by taking the larger of a gas estimate and a liquid estimate does not represent the actual flow regime.

What sizing does not fix: installation and scenario review

A correctly sized valve still chatters if inlet piping loses more than the allowed pressure drop before the nozzle, or if the outlet header back pressure rises above the selected style’s limit. The relieving study must list every scenario and mark the governing one; the fire case, where heat input sets the rate, frequently governs a vessel sized for a smaller process upset. Body geometry must remain drainable, and the seat must reseat bubble-tight after a relief event—neither property is guaranteed by the orifice letter alone.

Sizing verification: what the datasheet must carry

Sizing item

What the datasheet must state

Verification / source

Governing scenario

Scenario list per API 521; worst case marked

P&ID, relieving study, HAZOP

Relieving rate W / Q

Mass or volumetric rate at relieving conditions

Process calculation

Pressure basis

Set pressure, overpressure %, P1 absolute

Governing code plus datasheet

Back pressure

Superimposed, built-up, constant or variable, total

Flare or collection-header study

Fluid properties

M, k, T, Z, viscosity, phase, flashing tendency

Process simulation at relieving conditions

Valve factors

Kd, Kb, Kc basis and source

Manufacturer certified curves

Orifice selection

API 526 letter, body size, pressure class

Sizing sheet attached to the purchase order

The general rule is that sizing is judged at the relieving condition, not at the nameplate set pressure. The orifice letter, the factors, and the governing scenario must all be written onto the datasheet before the valve is ordered; a DN50 flange is a connection, not a sizing result.

Safety Relief Valve Sizing: An API 520 Worked Example from Relieving Scenario to Orifice Selection

Figure 2: Required area compared against API 526 effective orifice areas; the selected letter is the smallest area that meets the calculated A.