TSG 92-2026 Mandatory Rules: Media Selection for Full Lift & Low Lift Safety Valves

2026-08-11 13:05:35
TSG 92-2026 Mandatory Rules: Media Selection for Full Lift & Low Lift Safety Valves

Understanding the New Safety Valve Compliance in China

Effective July 1, 2026, the TSG 92-2026 regulation has become the mandatory standard for pressure vessel safety valves. For international companies importing Chinese pressure equipment, understanding these media selection rules is critical for project audit and site safety.

Media Selection Criteria: The Two Strict Rules

According to the latest TSG standards, valve type selection is no longer optional based on cost, but mandatory based on media properties:

  • Full Lift Safety Valves (Mandatory): Required for compressible media including Gas, Steam, LNG, and any liquid media where the temperature exceeds its boiling point.
  • Low Lift Safety Valves (Permitted): Only allowed for pure liquid systems such as water, oil, or glycol pipelines where rapid volume expansion is not a risk.

Technical Comparison: Performance Data

Performance Index

Full Lift Safety Valve

Low Lift Safety Valve

Lift Height

≥ 1/4 Seat Throat Diameter

1/40 ~ 1/20 Throat Diameter

Discharge Coefficient (K)

0.75 – 0.81

0.14 – 0.3

Relief Capacity

6-10x higher

Limited to small flows

Critical Risk Alert for Cryogenic LNG Systems

Engineers should note that straight DA-series low-lift valves no longer comply with LNG storage standards. Shanghai Xiazhao Valve provides L-shaped full lift designs specifically engineered to meet TSG 92-2026 and GB/API 526 standards.